top of page
Final Device 3.png
DirectionsCard_Testing_edited.png
Consumer_device_wLogo+RCE.webp
2-devices_web5_edited.png
Product1.png

RCE uses patented light frequency technology to transdermally acquire a composite of cardiac biomarkers.


Our unique skin-derived approach, enhanced with deep learning techniques, analyzes and associates the transdermal derived optical signatures with cardiac conditions in real-time. This AI-coupled transdermal approach enables the potential application of our platform technology in various emergency care settings and remote monitoring applications.
 

Non-invasive assessment of myocardial injury in only

3 minutes

anytime, anywhere.

Infrared Spectroscopy

Infrared spectroscopy is a widely used and applied characterization technique in the fields of geology, chemistry, and materials research has the ability to probe into a material at the molecular level. Molecular spectroscopy is one of the cornerstones of analytical tools used to study structural and compositional chemistry. 

Our team of scientists have transformed the capabilities of this technology by discovering the interaction between mid-infrared (MIR) radiation with matter, and invented the world’s only mid-infrared spectrophotometric sensor configured within a wrist wearable.

Infrasensor

Infrasensor is a non-invasive wrist-worn device intended for the detection of high-grade obstructive Non-ST Elevation Acute Coronary Syndrome (NSTE-ACS).


The device is intended to aid healthcare providers in evaluating symptomatic patients in acute care settings by providing supplemental information for the early identification of high-grade obstructive NSTE-ACS. High-grade obstructive NSTE-ACS includes acute coronary syndromes due to severe obstructive coronary artery disease, including total coronary artery occlusion.


The working principle of the Infrasensor is based on molecular infrared spectroscopy that uses an optical configuration called total internal reflection to assess a Transdermal Derived Infrared Spectrophotometric (TDIS) waveform. The detected infrared light waveform is transmitted from the on-device electronics unit to a secure cloud server where it is processed and analyzed to detect physiologic signals associated with high-grade obstructive NSTE-ACS.

 

Note: Infrasensor is currently an investigational device used for research purposes only. RCE is working closely with clinical and regulatory affairs to validate the safety and effectiveness prior to de novo pre-market clearance.

Device Exploded 2_edited.png

The future: Infrasensor-home 

Consumer_device_wLogo_edited.jpg

At RCE, we envision a future where cardiovascular disease can be better managed by patient’s cardiologist from the comfort of their own homes, providing peace of mind without the need for frequent visits to medical centers. To achieve this, we are developing a compact, wearable device that allows patients to continuously monitor their health in real-time. We believe this innovation will significantly enhance the quality of life for heart patients and substantially reduce health risks.

Licensing opportunities are available towards integrating our AI-based sensor technology with current patch/watch based wearables

Device Exploded 2_edited.png

Clinical Evidence

Clinical Evidence for Acute Care Heart Attack Diagnostics

Infrasensor for Detecting Non-ST Segment Elevation Acute Coronary Syndromes

Partho P Sengupta, Ankush Diwakar Jamthikar, Naveena Yanamala, Kameswari Maganti, Jitto Titus, Sanjeev Bhavnani, Shantanu Sengupta, A Wearable Infrared Sensor for Detecting Non-ST Segment Elevation Acute Coronary Syndromes, medRxiv 2025.12.24.25342991

First-in-human Transdermal Troponin-based assessment in STEMI and NSTEMI patients

Shantanu Sengupta, Siddharth Biswal, Jitto Titus, Atandra Burman, Keshav Reddy, Mahesh C Fulwani, Aziz Khan, Niteen Deshpande, Smit Shrivastava, Naveena Yanamala, Partho P Sengupta, A novel breakthrough in wrist-worn transdermal troponin-I-sensor assessment for acute myocardial infarction, European Heart Journal - Digital Health, Volume 4, Issue 3, May 2023, Pages 145–154.

10-hospital prospective observational study in healthy US subjects with a normal cTnI and in patients with an elevated cTn

William Franklin Peacock, Karina Melissa Soto-Ruiz, Allan S. Jaffe, Brian R. Tiffany, Simon A. Mahler, Brian W. Patterson, Alan HB Wu, Robert Christenson, A rapid non-invasive wearable device for assessing cardiac troponin, Clin Exp Emerg Med., 2024 September 06

First Continuous Monitoring in an Induced Heart Attack with a transdermal Infrared wearable

Li K, Morales-Garza M, Cardoso C, Moctezuma-Ramirez A, Burman A, Titus J, Elgalad A, Perin E. Early Changes in Acute Myocardial Infarction in Pigs: Achieving Early Detection with Wearable Devices. Diagnostics (Basel). 2023 Mar 7;13(6):1006. doi: 10.3390/diagnostics13061006. PMID: 36980316; PMCID: PMC10046897.

Translational Research in non-invasive detection of cardiac biomarkers and transdermal assessment of elevated cardiac Troponin

Titus, J., Wu, A.H.B., Biswal, S. et al. Development and preliminary validation of infrared spectroscopic device for transdermal assessment of elevated cardiac troponin. Commun Med 2, 42 (2022).

Translational Research

Non-Invasive Multiplexed Real-Time Threshold Detection of Cardiac, Renal, and Metabolic Biomarkers via Wrist-Worn Infrared Spectroscopy

Jitto Titus, PhD, Jessie Katz, Karina Soto-Ruiz, Robert Christenson PhD, Alan HB Wu, PhD, Allan S., Jaffe, MD, and W. Frank Peacock, MD, Non-Invasive Multiplexed Real-Time Threshold Detection of Cardiac, Renal, and Metabolic Biomarkers via Wrist-Worn Infrared Spectroscopy 

Biomarkers and Personalized Medicine in Cardiovascular Disease Symposium - 2023

Exploration of a rapid transdermal wearable in assessment of cardiac injury

Exploration of a rapid transdermal wearable in assessment of cardiac injury

American College of Cardiology (ACC) Scientific Session - 2024

THE PROMISE OF CONTINUOUS TRANSDERMAL CARDIAC INJURY BIOMARKER MONITORING DURING PCI: FIRST REAL-WORLD EXPERIENCE

THE PROMISE OF CONTINUOUS TRANSDERMAL CARDIAC INJURY BIOMARKER MONITORING DURING PCI: FIRST REAL-WORLD EXPERIENCE

Conference Posters

American Heart Association conference - 2022

Tropsensor: A Rapid Non-Invasive Transdermal Solution For Troponin Measurement

Tropsensor: A Rapid Non-Invasive Transdermal Solution For Troponin Measurement

Biomarkers and Personalized Medicine in Cardiovascular Disease Symposium - 2023

Exploration of a rapid transdermal wearable in assessment of cardiac injury

Exploration of a rapid transdermal wearable in assessment of cardiac injury

UT Southwestern Medical Center conference ACTS - 2023

Rapid Screening Tool for Identifying Acute Myocardial Injury: An Exploratory Study Evaluating the Ability of a Novel, Noninvasive Device to Detect Cardiac Troponin

Rapid Screening Tool for Identifying Acute Myocardial Injury: An Exploratory Study Evaluating the Ability of a Novel, Noninvasive Device to Detect Cardiac Troponin

American Heart Association conference - 2023

STUDY OF PERI-RESUSCITATION TROPONIN AND OUTCOMES (SANTO) PROOF-OF-CONCEPT STUDY

STUDY OF PERI-RESUSCITATION TROPONIN AND OUTCOMES (SANTO) PROOF-OF-CONCEPT STUDY

American College of Cardiology (ACC) Scientific Session - 2024

THE PROMISE OF CONTINUOUS TRANSDERMAL CARDIAC INJURY BIOMARKER MONITORING DURING PCI: FIRST REAL-WORLD EXPERIENCE

THE PROMISE OF CONTINUOUS TRANSDERMAL CARDIAC INJURY BIOMARKER MONITORING DURING PCI: FIRST REAL-WORLD EXPERIENCE

NASA - 2024

NON-INVASIVE PROTEIN MEASUREMENT BY TRANSCUTANEOUS SENSOR

NON-INVASIVE PROTEIN MEASUREMENT BY TRANSCUTANEOUS SENSOR

Intellectual Property

To date, RCE has been able to secure the following patents:

US 12,201,419

Patents the trend analysis for continuously acquired transdermal signals.

US 12,138,051

Patents the calibration techniques for reliable operations of transdermal infrared spectrophotometric wearables, also secures calibrating biomarker concentration levels based on association curves derived from blood comparisons

US D1,028,251

Secures the design elements for the point of care Infrasensor wearable

US 11,257,591 B2

Secures underlying physics for transdermal biomarker detection, and secures the wavelengths for Troponin and h-FABP

bottom of page